ANASYS2020R2 mesh has script error problem

created at 11-27-2021 views: 8

Problem description

During the calculation of workbench2020r2, the following screen suddenly appeared:

script error

Solution

The plan is as follows:

Manually register the DLLs listed below by starting a Command Prompt (DOS) with “run as administrator”, then typing:

regsvr32.exe ole32.dll
regsvr32.exe atl.dll
regsvr32.exe oleaut32.dll
regsvr32.exe scrrun.dll
regsvr32.exe jscript.dll
regsvr32.exe vbscript.dll

make sure they all say succeed

Now open regular CMD Prompt, and type the following command:

move “%appdata%\ansys” "%appdata%\ansys.old"

When solving, both normal CMD and administrator mode CMD can be used, just call the interface directly with win+R. Above codes can be entered one by one.

created at:11-27-2021